I. Troubleshooting sequence for dehumidifier failure to dehumidify: 1. Ventilation system failure; 2. Electrical system failure; 3. Refrigeration system failure; 4. Compressor failure;

I. Troubleshooting sequence for dehumidifier failure to dehumidify:
  1. Ventilation system failure:
  ① Inlet and outlet grilles: A. Man-made damage or aging cracking; B. Severe obstruction of air intake or outlet;
  ② Air filter: Blocked or damaged by dust;
  ③ Evaporator: A. Dust accumulation on evaporator condenser fins; B. Ice formation on evaporator surface;
  ④ Fan motor: A. Capacitor damage; B. Fan motor seizure; C. Rotor and shaft looseness; D. Shaft bending and deformation; E. Bearing damage; F. Winding burnout;
  ⑤ Fan blades: A. Loose fixing screws; B. Fan blade deformation or damage; C. Severe dust accumulation on fan blades, seriously affecting air volume; D. In small dehumidifiers, fan blades can also be jammed due to severe dust accumulation.
  2. Electrical system failure:
  ① Compressor and fan not rotating: A. Power cut off; B. Switch not turned on; C. Socket disconnection; D. Low voltage; E. Circuit breaker tripped; F. Fuse blown.
  ② Compressor not rotating, fan rotating: A. Starter failure; B. Capacitor failure; C. Overload protection.
  ③ Compressor and fan are running: Refrigeration system failure.
  3. Refrigeration system failure:
  ① Total refrigerant leakage;
  ② Refrigeration system blockage: A. Dirt blockage; B. Oil blockage; C. Welding blockage;
  ③ Excessive refrigerant;
  ④ Compressor has no displacement (failure).
  4. Compressor failure:
  ① Poor compression, gas leakage between high and low pressure chambers;
  ② Running parts damaged, compressor seizure.
II. Troubleshooting sequence for increased noise in dehumidifier:
  1. Uneven ground, dehumidifier not placed steadily;
  2. Loose parts on the dehumidifier;
  3. Foreign objects inside the dehumidifier;
  4. Damage or deformation of fan blades causing dynamic imbalance;
  5. Starter failure;
  6. Collision between pipelines;
  7. Fan lacks oil;
  8. Fan bearing failure;
  9. Excessive compressor noise;
  10. Excessive refrigerant or lubricating oil filling, causing liquid hammer.
 III. Troubleshooting sequence for dehumidifier operating normally but dehumidification effect deteriorating:
  1. Severe dust accumulation in the air filter, air flow obstruction;
  2. Outlet obstruction, air flow obstruction;
  3. Fan speed slows down;
  4. Poor room sealing, large amount of outdoor humid air entering;
  5. Excessive room area;
  6. Excessive moisture-releasing objects in the room;
  7. Excessive dust accumulation on evaporator fins, reducing the effect of freezing dehumidification;
  8. Frosting on the evaporator surface;
  9. Excessive oil accumulation in the evaporator, reducing the effect of refrigeration dehumidification;
  10. Insufficient refrigerant charge;
  11. Refrigerant leakage;
  12. Incorrect capillary tube specification, larger tube diameter, insufficient throttling pressure reduction;
  13. Ice blockage in the refrigeration system;
  14. Partial blockage or leakage in the refrigeration system;
  15. Air in the refrigeration system;
  16. Poor compressor compression, reduced displacement.
 IV. Troubleshooting sequence for dehumidifier leaking water to the ground:
  1. Dehumidifier is not balanced, the water tray is excessively tilted, causing water to overflow;
  2. The drain hole or drain pipe of the water tray is blocked;
  3. The water tray is damaged and leaking;
  4. Water leakage at the water pipe connection or aging and cracking of the water pipe.
 V. Troubleshooting sequence for dehumidifier compressor failing to start when powered on:
  1. Power failure, low voltage;
  2. Circuit fuse blown or switch damaged;
  3. Starting capacitor damaged;
  4. Overheat protection not reset or malfunctioning;
  5. Various relays not reset or malfunctioning;
  6. Motor winding open circuit or burnout.

 

Effect of ambient humidity on batteries

Generally, the ambient humidity should not exceed 90%, otherwise it is easy to condensation, affecting the insulation performance. This will also accelerate the rusting of terminals.
Problem. In this case, a dehumidifier or dehumidification equipment should be used to dehumidify the room, so that the ambient humidity reaches the ideal state.

Generally, battery manufacturers require the application of anti-rust grease to the terminals during battery installation to achieve anti-rust and lubrication effects.
In high-humidity environments, it can also enhance insulation to some extent.

Furthermore, using batteries in excessively dry areas accelerates the drying of AGM batteries and easily leads to static electricity, which
poses an arcing risk to high-voltage battery packs.


message

online message

Dear customers, if you have any comments and suggestions on our products or services, please tell us in time, we will contact you as soon as possible

Submission