All product design use of microcomputer automatic control technology, intelligent fuzzy control system

Products

Products


The workstation frame is made of Q235 carbon steel, with drawers and filing cabinets. The desktop adopts a fully open workstation design, using a high-quality Q235 carbon steel tabletop that is antibacterial and corrosion-resistant. The purification station is made of Q235 carbon steel and has a sealed structure. The purification station is designed with shelves for convenient file storage. The workstation monitors indoor cleanliness via a turbidity sensing probe, providing real-time monitoring and control of indoor air cleanliness. The purification cabinet is also equipped with an air quality sensor, effectively detecting both ambient and cabinet air quality. The dual-column independent structure allows for separate file disinfection. The product is designed with a 7-inch touch screen for independent control of individual chambers or simultaneous control of multiple chambers, along with a timer function. It offers intelligent control for convenient and safe operation. The workstation purification system consists of a bag filter, a photocatalytic ionization purification unit, and an activated carbon filter. This system efficiently removes paper scraps and PM2.5 from the air during file sorting, with a purification efficiency exceeding 99% and ozone release less than 0.1 mg/m³. A nano photocatalytic sterilization device and fan effectively sterilize, disinfect, and remove TVOC, with a sterilization rate exceeding 99%. The workstation purification unit is easy to maintain. The bag filter requires cleaning and maintenance after a period of use (7-15 days, depending on the amount of dust in the work environment) when the dust accumulation reaches saturation. The electronic purification components in the workstation purification unit are cleaned after dust saturation. Cleaning and drying do not affect the purification efficiency. The activated carbon gas filter in the workstation purification unit is replaced after dust saturation.


The sorting table is made of high-quality carbon steel, with drawers and file cabinets. The desktop adopts a fully open workstation design, and the countertop is made of high-quality steel, which is antibacterial and corrosion-resistant; the purification cabinet adopts high-quality steel material, with a closed structure, and the purification cabinet is designed with partitions for convenient file placement. The sorting table can complete the detection of indoor cleanliness through turbidity sensing probes, and monitor and control the indoor air cleanliness in real time; the purification cabinet is also equipped with an air quality sensor, which can effectively detect the air quality and the air quality inside the cabinet. It has a three-column independent structure, which can be used for file disinfection separately; the product is designed with a 7-inch touch screen, which can independently control a single chamber or simultaneously control multiple chambers. It also has a timing function, which can complete the intelligent control of the three columns separately, making it easy to operate and safe to use. The sorting table purification system consists of a bag filter, a photohydrogen ion purification unit, and an activated carbon filter, which can efficiently remove paper scraps and PM2.5 in the air during the sorting process, with a purification efficiency of over 99%, and ozone release <0.1mg/m³; using a nano photohydrogen sterilization device + fan structure, it can effectively sterilize, disinfect, and remove TVOC, with a sterilization rate >99%. The sorting table purification unit is easy to maintain. After a period of use (7-15 days, depending on the amount of dust in the working environment), the bag filter will be saturated with dust, and the filter needs to be cleaned and maintained. The electronic purification part of the sorting table purification unit is cleaned after the dust is saturated. After cleaning and drying, it does not affect the purification efficiency of the product. The activated carbon gas filter in the sorting table purification unit is replaced after the dust is saturated.


1. Users can operate the book sterilization process independently; 2. Sterilization can be completed within 30 seconds; 3. Digital buttons, a light touch is enough to start sterilization. 4. The operation starts with various bacteria spread across the book interface, and the bacteria gradually decrease to zero, ending the sterilization process; 5. Made of 100% environmentally friendly aluminum material, it is more beautiful. At the same time, it can achieve secondary light reflection to enhance the sterilization effect; 6. The sealed cavity cabinet design solves the problem of high noise generated by the existing book sterilizer. The noise during the operation of the sterilizer does not exceed 50 decibels. 7. Using the UV-C band with the best short-time sterilization rate, the product achieves a sterilization rate of over 99.9% within 30 seconds in professional testing institutions; 8. Equipped with 8 or more ultraviolet lamps, high book irradiation coverage; 9. Using our company's self-developed technology, the lifespan of the ultraviolet lamp is guaranteed to be over 15,000 times, and the lifespan tested by foreign testing institutions can reach over 30,000 times. Compared with similar products, the lifespan is increased by 4-6 times. 10. Using plant bactericides harmless to the human body to enhance the sterilization effect, and at the same time remove carcinogens such as xylene and ammonia from books; 11. High-efficiency dust collection filter, intercepting tiny molecules, does not produce harmful substances such as ozone or carbon dioxide, and keeps the air in the sterilization room clean; 12. The method of fixing books is a simple and easy-to-insert semi-automatic vertical bookshelf, which better fixes books of different thicknesses and makes it easier to place books; 13. Use a fan to gently blow the bottom of the book, so that the book is gradually and evenly blown open, increasing the sterilization rate of the inside of the book, and at the same time shaking off the dust outside the book and various impurities inside; 14. Using the internal air circulation method to prevent external dust from entering the sterilization room and polluting the books during sterilization; 15. The machine must be equipped with an anti-UV material glass viewing window to prevent ultraviolet light leakage and observe the entire sterilization process; 16. For easy movement, the sterilizer must have mobile wheels at the bottom of the machine body. Considering safety and stability, the four wheels must have wheel lock devices to fix the equipment; 17. Built-in 5-inch functional LCD screen, displaying the sterilization time and sterilization status in graphic and digital form; 18. The sterilization operation must not leave scratches or any damage marks on the book cover and inner pages; 19. For easy replacement of ultraviolet lamps (UV-C), a built-in automatic replacement prompt function is provided, and the number of times the lamp has been used can also be understood; 20. Adjust the sterilization time in units of 10 seconds, up to 60 minutes; 21. The machine has a sterilization progress countdown to prompt the progress of the sterilization operation; 22. The number of books sterilized at one time can reach more than 4, and the book sizes are 8K and 12K, etc., to meet the sterilization requirements of books of different sizes; 23. To prevent the user from opening the sterilization chamber door during the sterilization process, a safety device must be set to immediately stop operation; 24. The buttons used by the staff must be hidden inside the upper cabinet to prevent readers from arbitrarily changing the disinfection time.


1. Users can operate the book sterilization process independently; 2. Sterilization can be completed within 30 seconds; 3. Digital buttons, a light touch is enough to start sterilization. 4. The operation starts with various bacteria spread across the book interface, and the bacteria gradually decrease to zero, indicating the end of the sterilization process; 5. Made of 100% environmentally friendly aluminum material, it is more aesthetically pleasing. At the same time, it can achieve secondary light reflection to enhance the sterilization effect; 6. The sealed cavity cabinet design solves the problem of high noise generated by existing book sterilizers. The noise during operation does not exceed 50 decibels. 7. Using the UV-C band with the best short-time sterilization rate, it achieves a sterilization rate of over 99.9% within 30 seconds according to professional testing institutions; 8. Equipped with 8 or more ultraviolet lamps, ensuring high book irradiation coverage; 9. Using our company's self-developed technology, the lifespan of the ultraviolet lamp is guaranteed to be over 15,000 times, and foreign testing institutions have tested the lifespan to be over 30,000 times. Compared with similar products, the lifespan is increased by 4-6 times. 10. Using plant bactericides harmless to the human body to enhance the sterilization effect, while removing carcinogens such as xylene and ammonia from books; 11. High-efficiency dust collection filter, intercepting tiny molecules, preventing the generation of harmful substances such as ozone or carbon dioxide, and maintaining the cleanliness of the circulating air in the sterilization chamber; 12. The method of fixing books is a simple and easy-to-insert semi-automatic vertical bookshelf, which better fixes books of different thicknesses and makes it easier to place books; 13. Using a fan to gently blow the bottom of the book, making the book gradually and evenly spread out, increasing the sterilization rate of the inside of the book, and at the same time shaking off the dust and various impurities on the outside and inside of the book; 14. Using an internal air circulation method to prevent external dust from entering the sterilization chamber and contaminating the books being sterilized; 15. The machine must be equipped with an anti-UV material glass viewing window to prevent ultraviolet light leakage and allow observation of the entire sterilization process; 16. For easy movement, the sterilizer must have mobile wheels at the bottom. Considering safety and stability, the four wheels must have wheel lock devices to fix the equipment; 17. Built-in 5-inch functional LCD screen, displaying sterilization time and status in graphic and digital form; 18. The sterilization process must not leave scratches or any damage marks on the book cover and inner pages; 19. For easy replacement of ultraviolet lamps (UV-C), a built-in automatic replacement prompt function is provided, and the number of times the lamp has been used can also be checked; 20. Adjust the sterilization time in units of 10 seconds, up to a maximum of 60 minutes; 21. The machine has a sterilization progress countdown to indicate the progress of the sterilization process; 22. The number of books sterilized at a single time can reach more than 4, and the book sizes such as 8K and 12K meet the sterilization requirements of different sizes of books; 23. To prevent the user from opening the sterilization chamber door during the sterilization process, a safety device must be installed to immediately stop operation; 24. The buttons used by the staff must be hidden inside the upper cabinet to prevent readers from arbitrarily changing the disinfection time.


1. Users can operate the book sterilization process independently; 2. The sterilization process can be completed within 30 seconds; 3. Digital buttons, a light touch can start sterilization. 4. The operation starts with various bacteria spreading on the book interface, and the bacteria gradually decrease to none, ending the sterilization operation; 5. Made of 100% environmentally friendly aluminum material, it is corrosion-resistant, aging-resistant, and has a smooth and beautiful surface. At the same time, it can achieve secondary reflection of light, enhancing the sterilization effect, 6. The sealed cavity cabinet design solves the problem of high noise generated by the existing technology book sterilizer. The noise during the operation of the sterilizer does not exceed 50 decibels. 7. Using the UV-C band with the best sterilization rate in a short time, the product achieves a sterilization rate of over 99.9% within 30 seconds in a professional testing institution; 8. Equipped with 10 or more ultraviolet lamps, high book irradiation coverage; 9. Using our company's self-developed technology, the lifespan of ultraviolet lamps is guaranteed to be over 150 million times, and the lifespan tested by foreign testing institutions can reach over 30,000 times. Compared with similar products, the lifespan is increased by 4-6 times. 10. Using plant bactericides harmless to the human body, enhancing the sterilization effect, and removing carcinogens such as xylene and ammonia from books; 11. High-efficiency dust collection filter, intercepting small molecules, does not generate harmful substances such as ozone or carbon dioxide, maintaining the cleanliness of the circulating air in the sterilization room; 12. The way to fix books is a simple and easy-to-insert semi-automatic longitudinal bookshelf, which better fixes books of different thicknesses and makes it easier to place books; 13. Using a fan to gently blow the bottom of the book, making the book gradually evenly blown open, increasing the sterilization rate inside the book, and at the same time, it can shake off the external dust and various internal residues of the book; 14. Using internal air circulation to prevent external dust from entering the sterilization room and polluting the books during sterilization; 15. The machine must have an anti-UV material glass viewing window to prevent ultraviolet light leakage and observe the entire sterilization process; 16. For easy movement, the sterilizer must have casters on the bottom of the machine body. Considering safety and stability, the four casters must have wheel locking devices to fix the equipment; 17. Built-in 5-inch functional LCD screen, displays the sterilization time and sterilization status in graphic and digital form; 18. The sterilization operation shall not leave scratches or any damage marks on the book cover and inner pages; 19. For easy replacement of ultraviolet lamps (UV-C), a built-in automatic replacement prompt function is provided, and information on the number of times the lamp has been used can also be obtained; 20. Adjust the sterilization time in units of 10 seconds, up to 60 minutes; 21. The machine has a sterilization progress countdown to indicate the progress of the sterilization operation; 22. The number of books sterilized per time can reach more than 6, and the book sizes are 8K and 12K, meeting the sterilization requirements of books of different sizes; 23. To prevent the user from opening the sterilization room door during the sterilization process, a safety device must be set to immediately stop operation; 24. The buttons used by the staff must be hidden inside the upper cabinet to prevent readers from arbitrarily changing the disinfection time.

< 12345 > proceed page

message

online message

Dear customers, if you have any comments and suggestions on our products or services, please tell us in time, we will contact you as soon as possible

Submission